The FLEXmax 60 is the latest innovation in Maximum Power Point Tracking (MPPT) charge controllers from OutBack Power Systems. The FLEXmax 60’s innovative MPPT algorithm is both continuous and active, increasing your renewable energy yield up to 30%. Thanks to enhanced cooling, the FLEXmax 60 can operate at its full 60 amp maximum current rating in ambient temperatures as high as 104°F (40°C).
Included in the FLEXmax 60 are all of the features first developed by OutBack Power in the revolutionary MX60, such as support for a wide range of nominal battery voltages and the ability to step-down a high voltage solar array to recharge a low voltage battery. A built-in backlit display shows status information at the touch of a button. Enhanced network communications allow the FLEXmax 60 to be remotely programmed via the optional MATE system display and controller.
The new FLEXmax 60 is the only choice when you demand a high performance, efficient and customisable charge controller for your advanced power system.
| Nominal battery voltage | 12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up) |
| Maximum output current | 60 amps @ 104º F (40ºC) with adjustable current limit |
| Maximum solar array STC nameplate | 12 VDC systems 900 Watts / 24 VDC systems 1800 Watts / 48 VDC systems 3600 Watts / 60 VDC Systems 4500 Watts |
| NEC Recommended Solar Array STC Nameplate | 12 VDC systems 750 Watts / 24 VDC systems 1500 Watts / 48 VDC systems 3000 Watts / 60 VDC Systems 3750 Watts |
| PV Open Circuit Voltage (VOC) | 150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum |
| Standby Power Consumption | Less than 1 Watt typical |
| Power Conversion Efficiency | 98.1% @ 60 Amps in at 48 VDC System voltage - Typical |
| Charging Regulation | Five Stages: Bulk, Absorption, Float, Silent and Equalization Voltage Regulation |
| Voltage Regulation Set points | 10 to 80 VDC user adjustable with password protection |
| Equalization Charging | Programmable Voltage Set point and Duration - Automatic Termination when completed |
| Battery Temperature Compensation | Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell |
| Voltage Step-Down Capability | Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input |
| Programmable Auxiliary Control Output | 12 VDC output signal which can be programmed for different control applications (Maximum of 0.2 amps DC) |
| Status Display | 3.1” (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total |
| Remote Display and Controller | Optional Mate or Mate2 with RS232 Serial Communications Port |
| Network Cabling | Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires) |
| Data Logging | Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage,Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours,and kW Hours of production |
| Hydro Turbine Applications | Consult factory for approved Turbines |
| Positive Ground Applications | Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications) |
| Operating Temperature Range | Minimum -40° to maximum 60° C (Power capacity of the controller is automatically derated when operated above 40° C) |
| Environmental Rating | Indoor Type 1 |
| Conduit Knockouts | One 1” (35mm)on the back; One1” (35mm) on the left side; Two 1” (35mm) on the bottom |
| Dimensions | 400H x 140W x 100D mm |
| Weight | 6.4kg |
| Options | Remote Temperature Sensor (RTS), HUB 4, HUB 10, MATE, MATE 2 |