Selectronic Energy Management Upgrade Kit


  • Model:

    EMMKII

  • Shipping Weight: 0.3kg
  • Manufacturer:
    Selectronic
  • Available
    (call for delivery time)

$396.00
Note: this product 
may be eligible for 

added rebates
!

Sold Out
Buy with confidence! secure online shopping
Secure online shopping
Selectronic

Electronic Energy Management Upgrade Kit

 

The Selectronic Energy Management Upgrade Kit has the ability to read, log, regulate and control your system from either the front panel of your SE inverter, a remote keypad, or remote computer, via a phone line and modem.

 

Features

 

  • Four general purpose outputs
  • Two general purpose analogue inputs
  • Inverter control
  • Three external current shunt inputs
  • Modem and serial interface
  • Logging functions
  • Remote keypad interface
  • Electrical Specifications
  • Control functions and settings

Technical Specifications

 

Electrical Characteristics
Parameter Energy Management MKII
Sink current on Outputs 1 – 4 (Relay coil current) 100mA maximum
Voltage on Outputs 1 – 4 (Relay coil voltage) 65V maximum
Operating voltage range on inputs 1 and 2 0 - 2.5VDC
Maximum voltage on inputs 1 and 2 without damage + /- 30V
Modem communication interface Modem communication interface
Current capability of the 8V power supply for the modem 0.4A maximum
Keypad communication interface RS422
RS422 Via 8V modem supply
Shunt 1 input voltage - 47.5mV to 150mV
Shunt 2 and 3 input voltage 0 to 75mV
Control Function and Setting
Parameter Steps / Resolution
1.Delay settings for inputs 1 and 2 when programmed to control outputs 1 – 4 or inverter on/off - [ 0 - 40 minutes ] 1 minute
1. Delay settings for battery voltage when programmed to control outputs 1 – 4 or inverter on/off - [0 - 40 minutes ] 1 minute
1.State of charge in batteries setting when programmed to control outputs 1 – 4 or inverter on/off - [0 - 101 %] 1 %
2.Regulator boost, float & equalize voltage setting with 12V, 24V and 48V. Range 13-16.8V, 26-33.6V and 52-67.2V respectively. 0.1 V
Generator change over delay setting - [ 0 - 250 sec] 10 sec
Minimum generator run time setting - [ 0 - 40 minutes ] 1 minute
Lockout start time setting - 0:00 to 23:00 1 hr
Lockout end time setting - 0:00 to 23:00 1 hr
1.“Time of day” time settings when programmed to control outputs 1 – 4 or inverter on/off- 0:00 to 23:00 1 minute
1.“Time of day” day settings when programmed to control outputs 1 – 4 or inverter on/off. every day
3.Current readings on shunt 1 with 200A shunt-100A to 200A(400A surge) and with 100A shunt -50A to 100A (200A surge) 0.2A and 0.1A
3.Current reading on shunt 2 and 3 with 200A shunt-0 to200A, with 100A shunt -0 to 100A and with 50A shunt - 0 to 50A 0.2A, 0.1A and 0.1A

Notes:
1. These can be programmed separately for each of the four outputs and the inverter control.
2. Each output may be programmed to a different boost and float voltage.
3. All current shunts are 75mV.

 

Quality and Safety

 

  • Australian Made