GET A QUICK SOLAR QUOTE

Battery Backup Systemssolar components - archive

Sunny Island MPPT 40Amp Multi Voltage

 

AC and DC coupling optimally calibrated to each other and for the first time from one manufacturer: The Sunny Island Charger 40 developed by SMA can be used universally for 12, 24, and 48 V. Its broad DC input voltage range makes sensible system configuration possible for almost all PV modules. Thanks to the integrated MPP tracking, the charger guarantees an energy yield that is 15 – 30 % higher than that of conventional shunt and serial charge controllers. What is unique about charge controllers of this power range is the high protection class, the fanless operation, and the broad temperature range that makes worldwide use even in harsh ambient conditions possible. The easy installation and completely automatic customization of the controller settings by the Sunny Island make its commissioning very easy. Integrated in Sunny Island’s battery management, the battery is always optimally charged.

 

Efficient

 

  • Active MPP tracking
  • Efficiency over 98%

Robust

 

  • Indoor and outdoor through IP65
  • Fanless
  • Maximum nominal power up to 40 °C

Easy to use

 

  • Easy installation and commissioning
  • Automatic control via Sunny Island
  • Single point of operation from Sunny Island

Flexible

 

  • For 12 / 24 / 48 V > Up to four devices in parallel
  • Modular and extendable

Warranty

 

  • 5 years warranty

Technical Specifications

 

SIC40 MPT
Models 12V 24 V 48 V
Input - PV Generator
Max PV power 630 W 1250 W 2100 W
Max DC voltage 140 V DC
Optional MPPT voltage range 25 V - 60 V 40 V - 80 V 70 V - 110 V
Number of MPP trackers 1
Max PV power 40 A 40 A 30 A
Output - Battery
DC nominal power to 40°C 600 W 1200 W 2000 W
Nominal voltage range 12 V 24 V 48 V
Battery voltage range 8 - 15.6 V 16 - 31.5 V 36 - 63 V
Battery type Locked and self contained lead batteries
Max charging current 50 A 50 A 40 A
Continuous charging current 50 A 50 A 40 A
Charge control IUoU
Efficiency / Power Consumption
Max efficient 98 %
Euro-eta 97.3 %
Internal consumption during the day < 5 W
Internal consumption at night < 3 W
General Information
Dimensions 421W 310H x 143D mm
Protection class according to DIN EN 60529 IP65
Weight 10 kg
Device protection Short circuit / pole confusion / overload / over voltage and under voltage / over temperature and under temperature
Certificates and approvals CE
Display screen 1 x multicolored LED
Setting the parameters Plug and play in combination with SI 5048, SI 2224, SI 2012 (SIC-PB required) DIL switch with stand-alone applications
Parallel operation up to 4 devices over the sync bus
Interface for sunny Island sync bus sync bus piggy back (SIC-PB)
External temperature sensor optional (type KTY)
Ambient Conditions
Allowable ambient temperature during operation –25 °C to +60 °C
Humidity 0 % – 100 %

Details

  • Model: SIC40 MPT
  • Shipping Weight: 10kg
  • Manufacturer:
    SMA