The OutBack MX60 Maximum Power Point Tracking (MPPT) charge controller enables your PV system to achieve its highest possible performance. Rated for up to 60 amps of DC output current, the OutBack MX60 can be used with battery systems from 12 to 60 Volts DC with PV open circuit voltage as high as 125 Volts DC. The MX60's setpoints are fully adjustable to allow use with virtually any battery type, chemistry and charging profile.
The OutBack MX60 comes standard with an easy to use and understand display of the PV system’s performance. The four line, 80 character, backlit LCD display is also used for programming and monitoring of the system’s operation.
| Nominal Battery Voltages | 12, 24, 32, 36, 48, 54 or 60 VDC (Single model - selectable via field programming) |
| Output Current | 60 amps maximum with adjustable current limit for smaller systems |
| Maximum Solar Array Size | 12 VDC systems 800 Watts / 24 VDC systems 1600 Watts / 48 VDC systems 3200 Watts |
| PV Open Circuit Voltage (VOC) | 150 VDC absolute maximum coldest conditions / 140 VDC start-up and operating maximum |
| Standby Power Consumption | Less than 1 Watt |
| Charging Regulation | Five Stages: Bulk, Absorption, Float, Silent and Equalization |
| Voltage Regulation Set points | 10 to 80 VDC user adjustable with password protection |
| Equalization Voltage | Up to 5.0 VDC above Absorb Set point Adjustable Timer - Automatic Termination when completed |
| Battery Temperature Compensation | Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell |
| Voltage Step-Down Capability | Can charge a lower voltage battery from a higher voltage PV array |
| Power Conversion Efficiency | Typical | 98% at 60 amps with a 48 V battery and nominal 48 V solar array |
| Status Display | 3.1" (8 cm) backlit LCD screen with 4 lines with 80 alphanumeric characters total |
| Remote Interface | Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires) |
| Data Logging | Last 64 days of operation - amp hours, watt hours and time in float for each day along with total accumulated amp hours, kW hours of production |
| Hydro / Wind Turbine Applications | Consult factory for approved turbines |
Positive Ground Applications | Requires two pole breakers for switching both positive and negative conductors on both solar array and battery connections (HUB-4 and HUB-10 are not recommended for use in positive ground applications) |
| Operating Temperature Range | Minimum -40° to maximum 60° C (Power capacity of the controller is derated when above 25° C) |
| Environmental Rating | Indoor Type 1 |
| Conduit Knockouts | Two ½" and ¾" on the back; One ¾" and 1" on each side; Two ¾" and 1" on the bottom |
| Warranty | Standard 2 year / Optional 5 year |
| Weight | Unit | 11.6 lbs (5.3 kg) |
| | Shipping | 14 lbs (6.4 kg) |
Dimensions (H x W x L) | Unit | 13.5 x 5.75 x 4" (40 x 14 x 10 cm) |
| | Shipping | 18 x 11 x 8" (46 x 30 x 20 cm) |
| Options | Remote Temperature Sensor (RTS), HUB and MATE |